Provisioning

152-388-100-02, Issue 2

 

 

Resetting to Factory Default Values

All user options for the H2TU-C-388 List 1 (Table 5 on page 17) can be set to the factory default values using the MODE and SEL buttons. To set the user options to their default values:

1Press the SEL button for 6 seconds until the following message appears:

DFLT NO

2Press the SEL button while the DFLT NO message appears.

The message changes to DFLT YES indicating the factory default values are now in effect and the display returns to the normal mode.

To terminate the DFLT mode without setting the factory default values, do one of the following:

Press the MODE button to return to the normal display mode.

Wait 30 seconds for the unit to return to the normal display mode.

Displaying System Parameter Settings

To scroll through the current settings of all system parameters, press the MODE button for 3 or more seconds. The H2TU-C-388 displays the following parameters:

Software version number

List number

Type of frame pattern received from the DSX-1

Line code of the signal received from the DSX-1

All user-configured parameter settings

Loop attenuation threshold setting

Margin alarm threshold setting

Loopback Modes

See “Loopback Operation” on page 39 for instructions on using the MODE and SEL buttons to activate loopbacks.

USING A MAINTENANCE TERMINAL

Connecting to a Maintenance Terminal

A miniature, 3-pin, 210 Bantam-type jack on the front panel serves as a craft port and allows connection between the HiGain Line Unit and a maintenance terminal (ASCII terminal or PC running a terminal emulation program).

A210-to-DB-9 adapter is provided with every unit to facilitate the use of standard RS-232, DB-9 cables (see Figure 29 on page 51). Once connected to a maintenance terminal, you can access the maintenance, provisioning, and performance screens.

To connect to a maintenance terminal:

1Insert the 210-to-DB9 adapter into the RS-232 jack on H2TU-C-388 front panel.

2Connect an RS-232 cable to the adapter.

3Connect the other end of the cable to the serial port on the maintenance terminal.

4Start a terminal emulation program such as ProComm (emulating a VT100 terminal).

10

June 6, 2000

H2TU-C-388 List 1