Provisioning152-388-100-02, Issue 2

Table 5.

HiGain Line Unit List 1 Standard Config Screen Options (Continued)

 

 

 

 

 

Standard Config

Screen

Selection

Description

Display

Screen Options

Code

 

 

 

 

 

 

 

 

 

 

 

 

H2TU-R TLOS

TLOS

ENA

 

Enables a logic loopback at the H2TU-R when an LOS occurs at its DS1 input.

Loopback

 

 

 

 

See Figure 25 on page 38 for LOS/AIS response priorities.

 

 

 

DIS

 

Disables TLOS logic loopback.

 

 

 

 

 

Network

NLBP

AIS

 

Enables the H2TU-R to transmit AIS towards the CI for any network loopback.

Loopback Pattern

 

 

 

 

See Figure 25 on page 38 for LOS/AIS response priorities.

 

 

 

LOS

 

Enables the H2TU-R to transmit LOS towards the CI for any network loopback.

 

 

Table 6. HiGain Line Unit List 1 ADC Config Screen Options

 

 

 

 

 

 

ADC Config Screen

 

Screen

 

Selection

Description

Options

 

Display Code

 

 

 

 

 

 

 

 

 

Line Power Feed

 

PWRF

 

OFF

Disables powering to the HDSL2 pair.

 

 

 

 

ON

Keeps the HDSL2 line voltage at nominal -185 Vdc.

 

 

 

 

 

Remote Provisioning

RTPV

 

ENA

Enables remote provisioning.

 

 

 

 

DIS

Disables remote provisioning.

 

 

 

 

 

 

Bipolar Violation

 

BPVT

 

ENA

Enables BPVs and HDSL2 CRC errors at the DS1 input to be converted into

Transparency

 

 

 

 

DS1 BPVs at the DS1 output at the distant end. This makes HiGain

See “Bipolar

 

 

 

 

transparent to BPVs.

Violation

 

 

 

DIS

Disables BPV Transparency.

Transparency

 

 

 

 

 

(BPVT) Option” on

 

 

 

 

 

page 19.

 

 

 

 

 

 

 

 

 

 

 

DS1 BER Threshold

 

DBER

 

ENA

Enables the fixed 24-hour DS1 BER threshold.

 

 

 

 

DIS

Prevents the generation of a system alarm due to DS1 BER.

 

 

 

 

 

 

HDSL2 BER

 

HBER

 

1E-6

The Status LED flashes red when the Block Error Rate (BER) exceeds 10-6.

Threshold

 

 

 

 

 

See “HDSL2 BER

 

 

 

1E-7

The Status LED flashes red when BER exceeds 10-7.

Threshold (HBER)

 

 

 

NONE

Prevents generation of a system alarm due to BER.

Option” on page 19.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Special Loopback

 

SPLB

 

GNLB

Configures the HiGain system to respond to the generic inband loopback

Mode

 

 

 

 

codes.

 

 

 

 

A1LB and

Configures the HiGain system to respond to the inband loopback codes of

 

 

 

 

A2LB

the Teltrend addressable repeater.

 

 

 

 

A3LB

Configures the HiGain system to respond to the inband loopback codes of

 

 

 

 

 

the Wescom addressable repeater.

 

 

 

 

A4LB

Configures the HiGain system to respond to the inband loopback codes of

 

 

 

 

 

the Wescom Mod 1 addressable repeater.

 

 

 

 

A5LB

Configures the HiGain system to respond to the inband loopback codes of

 

 

 

 

 

the Teltrend Mod 1 addressable repeater.

 

 

 

 

 

SmartJack Loopback

LPBK

 

ENA

Enables the HiGain system to recognize all inband SmartJack (SMJK)

 

 

 

 

 

loopback commands.

 

 

 

 

DIS

Configures the HiGain system to ignore all inband SmartJack loopback

 

 

 

 

 

commands.

Continued

18

June 6, 2000

H2TU-C-388 List 1