Appendix A - Specifications152-388-100-02, Issue 2
LOOP ATTENUATION
Each loop has no more than 35 dB of loss at 196 kHz, with driving and terminating impedances of 135Ω (see Table 19 below).
Table 19. HDSL2 Cable Attenuation Chart
Cable Gauge | Loss at 196 kHz (dB/kft) | Ω per kft |
|
|
|
26/0.4 mm | 3.88 | 83 |
24/0.51 mm | 2.84 | 52 |
22/0.61 mm | 2.18 | 32 |
19/0.91 mm | 1.54 | 16 |
|
|
|
HIGAIN LINE UNIT CARD-EDGE CONNECTOR
Figure 28 shows the
| 219 | 119 | Frame ground |
|
Ground | 218 | 118 | Ground |
|
217 | 117 | Fuse alarm* |
| |
| 216 | 116 |
|
|
| 215 | 115 | Ring 1 | |
| 214 | 114 | Tip 1 | |
|
|
213 113
212 112
211 | 111 |
|
210 | 110 | Ring |
209 | 109 | |
Tip | ||
208 | 108 |
|
207 | 107 | Factory |
206 | 106 |
|
205 | 105 |
|
204 104 Management bus
203 103
202 | 102 | Ring 1 |
201 | 101 | HDSL2 Span |
Tip 1 |
200100
*Fuse alarm is normally floating (0 to 80 Vdc max.) and at
Figure 28. HiGain Line Unit
Network Management Control Bus
The
Some HiGain Line Unit features are affected when it is under management. Consult the management unit practice for further information.
50 | June 6, 2000 |