ENTER .

Provisioning

152-388-100-02, Issue 2

 

 

DS1 BER (DBER) Option. The DS1 BER alarm occurs when any of the DS1 or DSX-1 performance monitoring parameters listed in Table 7 exceed the counts shown for the 24-hour period between 12:00:00 AM through 11:59:59 PM. These thresholds correspond to a 10-6BER. All PM counters clear to zero at 12:00:00 AM or when Master Clear is selected.

Table 7. DS1/DSX-1 24-hour PM Threshold

Parameter

Threshold Count

 

 

CV-L (BPV)

133,400

ES-L, ES-P, PRM-NE, PRM-FE

648

SES-L, SES-P

100

UAS-P, UAS-L

10

 

 

Resetting the H2TU-C

Resetting the H2TU-C-388 to its original factory settings may cause interruption of service.

To reset the HiGain Line Unit to its original factory defaults:

1Type C to select the Config menu.

2 Use the and arrow keys to select Set Factory Defaults, then press

3Type Y if you are certain you want to reset the H2TU-C, or press N to cancel this action.

Monitor

Performance Event Log

Config

Inventory

Rlogon Help

 

----------------------

 

 

+

+

 

 

 

 

Standard Options ->

 

 

PairGain Options ->

 

Date and Time

->

 

Master Clear

 

 

Set Factory Defaults

----------------------+

 

 

+

SETTING FACTORY

DEFAULTS...SERVICE *MAY* BE INTERRUPTED! ARE YOU SURE (Y/N)?

ID: xxxx--xxxx--

xxxx--xxxx

04/15/00 12:30:01

H2TU-C

System: OK

Figure 9. Configuration Menu - Reset to Factory Defaults

20

June 6, 2000

H2TU-C-388 List 1