Testing | |
|
|
Special Loopback Commands
In addition to the GNLB loopback command mode, a HiGain system can be configured for one of five special loopback command modes. These are selected from the maintenance terminal System Settings screen (see Table 5 on page 17) or by using the MODE and SEL buttons (see Figure 27 on page 44). Once a loopback mode is activated, other loopback commands can be sent by a test set connected to the craft port of the
A1LB through A5LB are five special, addressable, repeater loopback modes which are supported by the
•A1LB (Teltrend) = Southwestern Bell
•A2LB (Teltrend) = Southwestern Bell
•A3LB (Wescom) = New England Telephone
•A4LB (Wescom Mod 1) = New York Telephone
•A5LB (Teltrend Mod 1) = Southern New England Telephone (SNET), Southwestern Bell, Pacific Bell
The A1LB loopback selection complies with that proposed for HDSL2 systems in the T1E1.4/92 recommendation with the following additions:
•Query loopback
•IOR (Intelligent Office Repeater) powerdown
•Four loopback
•Initiation from either end
•Repeating bit error signatures
•Alternate query loopback
These additions make A1LB identical to A2LB. A1LB is given a separate identity to allow future DS1/E1 enhancements to be added without affecting A2LB.
A5LB differs from A2LB in that A5LB does not block the arming code from exiting the
•Block the arming code (after 2 seconds) from exiting the
•Unblock the AIS code by executing the
A3LB differs from A4LB in that A3LB supports the additional
June 6, 2000 | 41 |