Monitoring System Activity and Performance152-388-100-02, Issue 2

Table 10. Acronyms Used on the HDSL2 Performance History Screens

Error Acronym

Description

ES

Errored Seconds

 

Seconds with HDSL2 CRC 1 or LOSW 1

SES

Severely Errored Seconds

 

Seconds with HDSL2 CRC 50 or LOSW 1

UAS

Unavailable Seconds

 

Based on 10 contiguous SES occurrences

CV

Code Violation

 

Total count of HDSL2 CRC errors

LOSWS

Loss of Sync Word Second

 

Seconds with LOSW 1

USING THE PERFORMANCE SCREENS TO VIEW ALARM DATA

To access the alarm history screens:

1Type P to select the Performance screen.

2Press the SPACEBAR to select an interface (H2TU-C DS1, H2TU-R DS1, H2TU-C HDSL2 or H2TU-R HDSL2), then press ENTER .

3Press the SPACEBAR until Alarm History is selected, then press ENTER .

Press N or P to page through the alarm history screens.

Press L to clear the selected alarm history screen.

30

June 6, 2000

H2TU-C-388 List 1