152-388-100-02, Issue 2

Provisioning

 

 

Table 5 describes the Standard Config screen options and lists their front-panel display codes. Table 6 on page 18 describes the ADC Config screen options. Selections in bold typeface are the factory default settings.

Table 5. HiGain Line Unit List 1 Standard Config Screen Options

Standard Config

Screen

Selection

Description

Display

Screen Options

Code

 

 

 

 

 

 

 

 

 

Loopback

LBTO

NONE

Disables automatic time-out cancellation of all loopbacks.

Timeout

 

20

Sets automatic cancellation of all loopbacks to 20 minutes after initiation.

 

 

 

 

60

Sets automatic cancellation of all loopbacks to 60 minutes after initiation.

 

 

120

Sets automatic cancellation of all loopbacks to 120 minutes after initiation.

 

 

 

 

Loop Attenuation

LATT

0 through 40 dB

Determines the maximum loop attenuation before an alarm is declared. The

Threshold

 

 

loop attenuation threshold can only be set through the HiGain HDSL2

 

 

 

maintenance screens.

 

 

35 dB

Default value. Zero disables the alarm.

 

 

 

 

Margin Threshold

MARG

0 to 15 dB

Determines the minimum allowable margin below which a system alarm can

 

 

 

occur. Zero disables the alarm.The Margin Alarm Threshold can only be set

 

 

 

through the HiGain HDSL2 maintenance screens.

 

 

4dB

Default value.

 

 

 

 

DS1 Frame

FRMG

AUTO

Configures the HiGain system to operate in an auto-framing (AUTO) mode. It

Formatting

 

 

detects and locks to both SF or ESF DS1 frame patterns. Line and path

 

 

 

performance parameters are maintained and displayed. Unframed payloads

 

 

 

will cause the ES-P and SES-P counters to increment.

 

 

SF

Configures the HiGain system to search for the SF framing pattern at its DS1

 

 

 

input.

 

 

ESF

Configures the HiGain system to search for the ESF framing pattern at its DS1

 

 

 

input.

 

 

UNFR

Configures the same as AUTO except unframed payloads do not cause the

 

 

 

ES-P and SES-P counters to increment.

DS1 Line Coding

DS1

AUTO

The H2TU-C-388 and H2TU-R monitor the incoming DS1 bit streams for the

(see “DS1 Line

 

 

B8ZS code. If the H2TU-R detects this code, the H2TU-C enters B8ZS output

 

 

mode. The H2TU-C reverts back to AMI output mode if no B8ZS codes are

Coding (DS1)

 

 

Option” on

 

 

received at the H2TU-R input for 5 seconds. Similarly, when the H2TU-C

 

 

detects the B8ZS code, the H2TU-R enters B8ZS mode and returns to AMI

page 19)

 

 

 

 

mode if no B8ZS code is received at the H2TU-C input for 5 seconds.

 

 

 

 

 

B8ZS

Places both the H2TU-C-388 and H2TU-R into B8ZS mode.

 

 

AMI

Places both the H2TU-C-388 and H2TU-R into AMI mode.

 

 

 

 

H2TU-C

EQL

0

Sets the Equalizer to DSX-1 for 0 to 132 feet.

Equalization

 

 

 

See “H2TU-C

 

133

Sets the Equalizer to DSX-1 for 133 to 265 feet.

Equalization

 

266

Sets the Equalizer to DSX-1 for 266 to 398 feet.

(EQL) Option.” on

 

 

399

Sets the Equalizer to DSX-1 for 399 to 532 feet.

page 19.

 

 

533

Sets the Equalizer to DSX-1 for 533 to 655 feet.

 

 

 

 

 

 

H2TU-R Line

RLBO

0 dB

Sets the DS1 receive level output toward the Customer Interface (CI). Can only

Buildout

 

 

be set through the HiGain HDSL2 maintenance screens.

 

 

-7.5 dB

Sets the DS1 RLBO level toward the CI to -7.5 dB.

 

 

-15 dB

Sets the DS1 RLBO level toward the CI to -15.0 dB.

 

 

 

 

Alarm Pattern

ALMP

AIS

Enables the HiGain system to output an AIS payload at its DS1 ports for LOSW

 

 

 

and DS1 LOS. See Figure 25 on page 38 for LOS/AIS response priorities.

 

 

LOS

Enables the HiGain system to output an LOS condition at its DS1 ports for

 

 

 

LOSW and DS1 LOS.

 

 

 

Continued

H2TU-C-388 List 1

June 6, 2000

17