Testing

152-388-100-02, Issue 2

 

 

Manual Loopback Session

A manual loopback session allows you to select any one of the HiGain loopbacks listed in Table 15 on page 40 with the exception of SmartJack loopbacks, which can only be issued by inband commands.

Setting the Loopback Time-out Option

Before initiating a loopback session, verify that the Loopback Time-out parameter is set to the desired setting.

1Use the MODE and SEL buttons as described in “Setting Options through MODE and SEL” on page 9.

(The Loopback Time-out parameter is also user-selectable from the System Settings screen when using a maintenance terminal.)

2Select the desired setting:

NONE (time-out disabled)

20 minutes

60 minutes (default setting)

120 minutes

Activating Manual Loopback Mode

With the exception of SmartJack, any of the HiGain loopbacks can be executed using the MODE and SEL buttons.

When executing a manual loopback session using the MODE and SEL buttons:

The next loopback option can be displayed by pressing the MODE button, however, the previously activated loopback remains active until the SEL button is pressed, which activates the new loopback.

If neither button is pressed for a period of 30 seconds and no loopback is in effect, the manual loopback session terminates and the display returns to normal mode.

If any loopback is in effect, the 30-second time-out is inhibited. The active loopback and the manual loopback session continue until the loopback times out in accordance with the LBTO setting.

If there is an active loopback, pressing the MODE and SEL buttons for 3 or more seconds terminates any active loopback, ends the manual loopback session, and returns the display to normal mode.

To initiate a manual loopback session:

1Press both the MODE and SEL buttons on the front panel for at least 5 seconds. The following message appears on the front-panel display:

MAN LPBK NLO?

2Press SEL to activate NLOC. The display changes to MAN LPBK NLOC.

3Press MODE to advance to the next available loopback:

NRE? = NREM

CRE? = CREM

CLO? = CLOC

COL? = dual loopback at H2TU-C.

RUL? = dual loopback at H2TU-R.

42

June 6, 2000

H2TU-C-388 List 1