Front Panel152-388-100-02, Issue 2
Table 2.
Message | Full Name | Description |
SMJK | Remote SmartJack Loopback | |
|
| module. |
|
| |
DIAGNOSTIC MESSAGES |
| |
A = xx | Maximum Loop Attenuation | The Attenuation (A) message appears followed by xx, where xx is the |
|
| loop attenuation, measured in dB. |
ACQ | Acquisition | The multiplexers of the |
|
| synchronization over the HDSL2 loop. |
AnL | Acquisition n Loop | The multiplexers of the two devices are trying to establish |
|
| synchronization with each other, where n is the number of the span. |
ARM | HiGain System Armed | Armed to respond to Intelligent Repeater Loop (ILR) codes. |
BAD RT? | No Response from | The |
|
| conditions are normal. Therefore, the integrity of the |
|
| HDSL2 loop is questionable. |
FERR | Framing Bit Error Occurred | Framing bit error occurred at |
FLDL | Flash Download | Flash download of firmware updates. Contact Customer Service for |
|
| update procedures (see “Appendix D - Product Support” on page 54). |
HES | HDSL2 CRC Error | |
LBPV | Local Bipolar Violation | A bipolar violation has been received at the |
|
| Line Unit. |
M=xx | HDSL2 Loop Margin | Indicates the power of the received HDSL2 signal relative to noise (S/N |
|
| with respect to 21.5 dB). Any value of 6 dB or greater is adequate for |
|
| reliable system operation. |
MNGD | Managed | The HiGain Line Unit is under control of the |
|
| management unit. In this state, the |
|
| buttons are disabled. |
PWR FEED OFF | Power Feed Off | HDSL2 span power has been turned off by setting the PWRF option to |
|
| off, or HDSL2 span power has been turned off by use of the A2LB |
|
| Intelligent Office Repeater (IOR) Power Down code. |
PWR FEED ON | Power Feed On | Indicates that the HDSL2 loop is not grounded or shorted. |
SIG | Signaling | The transceivers of the |
|
| contact with each other over the HDSL2 loop. |
SnL | Signal n Loop | The transceivers of the two devices are trying to establish contact with |
|
| each other, where n is the number of the span. |
|
| |
SYSTEM INFORMATION MESSAGES (a) |
| |
CODE xxxx | Line Code: AMI or B8ZS | The line code that |
|
| DS1 option is set to AUTO. Otherwise, it mimics either of the other two |
|
| DS1 line code settings, Alternate Mark Inversion (AMI) or Bipolar with |
|
| |
FRM xxxx | Frame: SF, ESF, UNFR | Defines the type of frame pattern being received from the |
|
| SuperFrame (SF), Extended SuperFrame (ESF), Unframed (UNFR). |
LATT xx | Loop Attenuation | The current loop attenuation threshold setting measured in dB. |
LIST xx | HiGain Line Unit List Number | The list number xx. |
MARG xx | Margin | The current margin threshold setting measured in dB. |
VER x.xx | HiGain Line Unit Software Version | The software version number (x.xx). |
| Number |
|
|
|
|
(a)System information messages are displayed in scroll mode. To scroll through system information messages, press the MODE button for 3 or more seconds.
6 | June 6, 2000 |