Changing Alarm Settings and Thresholds

1.From the QFO-C Main Menu screen, type Ò4Ó and press Enter to select Alarms. The Alarms Screen (Figure 19) will appear.

2.Type Ò2Ó and press Enter to select Alarm Provisioning. The Alarm Provisioning Screen (Figure 21) will appear.

Setting the ES Threshold (15-Min.)

1.From the Alarm Provisioning Screen, type Ò1Ó and press Enter to select ES Threshold (15-Min.). The ES Threshold Screen (Figure 22) will appear. Type the number of desired setting and press Enter.

Shelf: Slot:

Total Access System

02/18/98 02:24:18

Unacknowledged Alarms: None

 

 

‘?’ - System Help Screen

 

Alarm Provisioning

 

1.

ES Threshold (15 Min.)

30

2.

SES Threshold (15 Min.)

15

3.

UAS Threshold (15 Min.)

15

4.

ES Threshold (24 Hours)

14400

5.

SES Threshold (24 Hours)

7200

6.

UAS Threshold (24 Hours)

7200

Selection:

Figure 21. Alarm Provisioning Screen

Shelf: Slot:

Total Access System

02:24:18 02/18/98

Unacknowledged Alarm: None

 

 

ES Threshold (15 Min.):

30

1.30

2.150

Selection:

? - System Help Screen

Figure 22. ES Threshold (15-Minute) Screen