Chapter 8. Remote/Management Menus

 

The following chart describes each command of the Unit

 

Access Table.

 

Table 8-1. Unit Access Table Commands

 

 

Command

What it does...

 

 

 

 

Add New Unit

Adds a new device to the table.

 

You must enter a device Unit ID, passcode, Unit type, and polled

 

flag. Unit type can be:

 

Standard (which supports any TSU/TDU Multiplexer and the ISU

 

512), or TSU Standalone (a single port TSU with no option card slot).

 

A passcode of 0 to 9999 for each device or DEFAULT may be

 

selected, which results in the default passcode being used (defined

 

as 0022 in Figure 8-1 on page 8-2).

 

Traps are normally sent from the unit in alarm to the TDU 120e. For

 

units in the Unit Access Table that are not chained directly to the

 

TDU 120e but are managed over Inband or the FDL, traps are not

 

automatically forwarded. Polling must be enabled on the TDU 120e

 

for these units in order to receive Traps on the NMS. The TDU 120e

 

can be configured to poll selected units for traps by enabling the

 

polled option when adding or modifying a unit entry.

 

 

Modify Unit

Allows unit ID, passcode, device type, and polled flag to be changed

 

for an existing entry in the table.

 

 

Delete Unit

Deletes an entry in the table.

 

 

Default Unit

Sets the default passcode for all devices in the table that have

Passcode

passcodes set to DEFAULT, or for any unit not listed in the table.

 

 

OK

Returns to the CONFIGURE AGENT menu.

 

 

61202156L2-1A

TDU 120e User Manual

8-3

Page 111
Image 111
ADTRAN TDU 120e user manual Unit Access Table Commands, Command What it does