Chapter 5. Configuration Menu
CTS
Used to control characteristics of CTS.
Choices: NORMAL, (see Table
FORCE ON
DCD
Data Carrier Detect. Indicates to the DTE when a valid signal is being received at the Network Inter- face.
Choices: NORMAL (see Table
FORCE ON
DSR
Data Set Ready. This signal indicates to the DTE when the DCE is turned on and ready for operations. Choices: NORMAL (see Table
FORCE ON
“0” INHIB
The Nx interface will detect an uninterrupted string of zeros (0s) being transmitted toward the network. If 0s are transmitted for more than 1 second, the TDU 120e will force 1s.
Choices: ON or OFF
INBAND MODE
The Nx56/64 port is capable of providing an inband communications channel (for
Choices: ON or OFF, ON DEMAND
TX CLK SOURCE
Controls the source of the clock used by the TDU 120e to accept transmit data from the DTE. The default option is INTERNAL.
If the application requires that the DTE device pro- vide the clock with the transmit data, the External setting is used.
Choices: INTERNAL, EXTERNAL
TDU 120e User Manual |