Chapter 2. Installation

The connection to ground of the supplementary equipment grounding conductor shall be in compli- ance with the rules for terminating bonding jumpers at Part K or Article 250 of the National Electrical Code, ANSI/NFPA 70.

Termination of the supplementary equipment grounding conductor is permitted to be made to building steel, to a metal electrical raceway system, or to any grounded item that is permanently and reli- ably connected to the electrical service equipment ground.

The supplemental grounding conductor shall be con- nected to the equipment using a number 8 ring termi- nal.

The terminal should be fastened to the grounding lug provided on the rear panel of the equipment.

The ring terminal should be installed using the ap- propriate crimping tool (AMP P/N 59250 T-EAD Crimping Tool or equivalent).

Do not use this product near water, such as in a wet basement.

For DC-powered devices, the supply power for the product must be installed near the equipment and be easily accessible.