ADTRAN TDU 120e user manual Data Port Identification, Edit the Data Field

Models: TDU 120e

1 146
Download 146 pages 37.58 Kb
Page 46
Image 46

Chapter 3. Operation

Edit the Data Field

You can edit data fields preceded by a colon (:). To edit a data field perform the following steps:

Step

Action

Result

 

 

 

 

 

 

1

Position the cursor on the submenu

The cursor moves to the data

 

item number and press Enter.

field (to the right of the

 

 

submenu item name).

 

 

 

2

Using the space bar, scroll to scan

The value settings display

 

the available value settings.

one-at-a-time in the data field

 

 

position.

 

 

 

3

When the desired value is

When the value is set, the

 

displayed in the data field position,

cursor moves back to the

 

press Enter to set that value.

submenu item position.

 

 

 

4

Select another submenu field or

This indicates the operation is

 

press Escape to return to the

complete.

 

submenu.

 

 

 

 

Exit Any Menu Field Operation or Display

Press Escape as many times as required to return to the desired menu level.

Data Port Identification

When configuring the unit, menu selections will include options from data port submenus. Selecting data ports is necessary because the TDU 120e uses a Slot-Port method to identify the data port the menu item is referencing. If a module containing a PBX DSX-1 option card with an Nx56/64 plug-on interface is installed in the option slot, it would be designated as:

DSX-1 Passthru (1.1) Where slot=1 and port=1.

The DSX-1 is located in the option slot and is the first port in that slot.

Nx56/64 (1.2)

Where slot=1 and port=2.

3-4