Table D.2: PCM-3780 Counter Mode
Counter Mode | M | N | O | P | Q | R | S | T | U | V | W | X |
|
|
|
|
|
|
|
|
|
|
|
|
|
Special Gate (CM6) | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Reload Source (CM5) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Repetition (CM4) | 0 | 0 | 0 | 1 | 1 | 1 | 0 | 0 | 0 | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Gate Control | N | L | E | N | L | E | N | L | E | N | L | E |
(CM15~CM12) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Count to TC once, then | Y | Y | Y |
|
|
|
|
|
|
|
|
|
disarm |
|
|
|
|
|
|
|
|
|
|
|
|
Count to TC twice, then |
|
|
|
|
|
| Y | Y | Y |
|
|
|
disarm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Count to TC repeatedly |
|
|
| Y | Y | Y |
|
|
| Y | Y | Y |
without disarming |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Gate input dose not gate | Y |
|
| Y |
|
| Y |
|
| Y |
|
|
counter input |
|
|
|
|
|
|
|
|
|
|
|
|
Count only during active |
| Y |
|
| Y |
|
| Y |
|
| Y |
|
gate level |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Start count on active gate |
|
| Y |
|
| Y |
|
|
|
|
|
|
edge and stop count on |
|
|
|
|
|
|
|
|
|
|
|
|
next TC |
|
|
|
|
|
|
|
|
|
|
|
|
Start count on active gate |
|
|
|
|
|
|
|
| Y |
|
| Y |
edge and stop count on |
|
|
|
|
|
|
|
|
|
|
|
|
second TC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Start count on active gate |
|
| Y |
|
| Y |
|
| Y |
|
| Y |
edge and stop count on |
|
|
|
|
|
|
|
|
|
|
|
|
inactive gate edge |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Reload counter from Load | Y | Y | Y | Y | Y | Y |
|
|
|
|
|
|
Register on TC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Reload counter on each |
|
|
|
|
|
| Y | Y | Y | Y | Y | Y |
TC, alternating reload |
|
|
|
|
|
|
|
|
|
|
|
|
source between Load and |
|
|
|
|
|
|
|
|
|
|
|
|
Hold Registers |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: Counter modes M, N, P, Q, S, T, V, W are identical to A, B, D, E, G, H, J, K.
46 |