C.6 Counter 0/1 Command Register

Base

 

PCM-3780 Register Format

 

 

Address +

15 14 13 12 11 10 9 8 7 6 5 4 3 2

1

0

HEX

 

 

 

 

6h

W

Counter 0 Command Register

 

 

 

 

C2

C1

C0

 

R

Counter 0 Command Register

 

 

Eh

W

Counter 1 Command Register

 

 

 

 

C2

C1

C0

RCounter 1 Command Register

1.C2 to C0 : Command Code

000= Disarm counter

001= Load counter from LOAD

010= Disarm and Save counter

100= Arm counter

101= Load and Arm counter

110= Save counter to HOLD

111= Reset counter

C.7 Counter Command Enable Register

Base

PCM-3780 Register Format

 

 

 

 

 

 

 

 

 

Address

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

+ HEX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20h W

Counter Command Enable Register

 

 

 

 

 

CE1

CE0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCounter Command Enable Register

1.CE1 to CE0: Counter Command Enable Bit

0= Not Select this counter

1= Select this counter

PCM-3780 User Manual

38

Page 46
Image 46
Advantech PCM-3780 manual Counter 0/1 Command Register, Counter Command Enable Register, C2 to C0 Command Code