51 Appendix D
D.6 Mode E Waveforms
Rate Generator with Level Gating
Mode E is identical to Mode D, except the counter will only count those
source edges that occur while the gate input is active. This feature allows
the counting process to be enabled and disabled under hardware control.
A square wave rate generator may be obtained by specifying the TC tog-
gled output mode.
SOURCE
COUNT
VALUE
TC OUTPUT
TC TOGGLED
OUTPUT
GATE
2L-1 L-2 K+1 K-1 210L
Mode E Waveforms
1 0 L K