AEG PV.500-MH manual 6.2Table of Faults, Temperature monitoring systems

Models: PV.500-MH

1 68
Download 68 pages 42.91 Kb
Page 38
Image 38
6.2Table of Faults

Protect PV.500-MH Operating Instructions

6.2Table of Faults

The monitoring systems listed below will cause the inverter to switch off, are self- acknowledging or signalling and are shown on the DOU with corresponding plain text:

Temperature monitoring systems

Fault/Message

Deac-

Self-

Signalling

DOU message

 

tivating

acknow-led

 

 

 

 

ging

 

 

IGBT 1 stack temperature warning

 

 

X

!Equipment temperature fault!

 

 

 

 

 

IGBT 2 stack temperature warning

 

 

X

!Equipment temperature fault!

 

 

 

 

 

IGBT 1 stack temperature fault

 

X

 

#Equipment temperature fault#

 

 

 

 

 

IGBT 2 stack temperature fault

 

X

 

#Equipment temperature fault#

 

 

 

 

 

IGBT supply air undertemperature

 

 

X

!Ambient temperature fault!

 

 

 

 

 

IGBT supply air temperature warning

 

 

X

!Ambient temperature fault!

 

 

 

 

 

IGBT supply air temperature fault

 

X

 

#Ambient temperature fault#

 

 

 

 

 

Unit exhaust air 1

 

 

X

!Equipment temperature fault!

temperature warning

 

 

 

 

 

 

 

 

 

Unit exhaust air 2

 

 

X

!Equipment temperature fault!

temperature warning

 

 

 

 

Unit exhaust air 1

 

X

 

#Equipment temperature fault#

temperature fault

 

 

 

 

 

 

 

 

 

Unit exhaust air 2

 

X

 

#Equipment temperature fault#

temperature fault

 

 

 

 

 

 

 

 

 

Equipment supply air undertempera-

 

 

X

!Ambient temperature fault!

ture

 

 

 

 

 

 

 

 

 

Unit supply air temperature warning

 

 

X

!Ambient temperature fault!

 

 

 

 

 

Unit supply air temperature fault

 

X

 

#Ambient temperature fault#

 

 

 

 

 

Temperature sensor fault

 

X

 

#Temperature sensor fault#

IGBT 1 stack

 

 

 

 

 

 

 

 

 

Temperature sensor fault

 

X

 

#Temperature sensor fault#

IGBT 2 stack

 

 

 

 

 

 

 

 

 

Temperature sensor fault

 

X

 

#Temperature sensor fault#

IGBT supply air temperature

 

 

 

 

Temperature sensor fault

 

X

 

#Temperature sensor fault#

unit exhaust air 1 temperature

 

 

 

 

 

 

 

 

 

Temperature sensor fault

 

X

 

#Temperature sensor fault#

unit exhaust air 2 temperature

 

 

 

 

Temperature sensor fault unit supply

 

 

X

#Temperature sensor fault#

air temperature

 

 

 

 

 

 

 

 

 

IGBT difference temperature

 

 

X

#IGBT difference temperature

deviation

 

 

 

dev.#

 

 

 

 

 

38 of 68

80000043212 BAL

Page 38
Image 38
AEG PV.500-MH manual 6.2Table of Faults, Temperature monitoring systems