:ANAPURNA L/XL | OPERATOR MANUAL |
8.4. Long Stand Still
This procedure must be carried out:
-If the engine’s “Stand Still Time” is 1 week or longer…
-If the vacuum pressure is going to be closed down…
SHUTDOWN
-Move the carriage to the Purge position.
-Flush cleaning solution through the heads:
-First purge the 4 right heads (Lc, Lm, W1, W2), close them,
and in the second stage, purge the remaining 4 left heads (K, C, M, Y).
-Finally, open the 4 right heads again, and purge all 8 heads together now. By doing so, you’ll have the most optimal cleaning pressure.
-Leave all ink valves in the “S” position, set the Solution valve to “I”.
-On the Engine’s Control Panel, perform a “Head
(the carriage will go to the highest position)
-Clean the Head Base Plate with a cloth
-Set the Vacuum Pressure to “0”. (Negative Pressure)
-Mount the “Capping Plate” underneath the Head Base Plate.
-use a plastic foil to wrap around the capping plate (new foil every time)
-place a support between the capping plate and the grid.
-bring down the carriage by turning manually, until it’s fixed.
(use some packing material as support)
-Push the emergency stop, and leave it pushed in!
-Switch OFF the main power, by using the
-Turn off the compressed air.
MAIN SWITCH
- THE ENGINE IS NOW READY FOR A LONG STAND STILL -