11.2.4. Feed Speed:
This is the forward speed of the conveyor belt between the print passes.
A Feed Speed of “500” is considered the default.
No changes have to be made, unless you print at a high speed/low pass,
and the conveyor belt is STILL feeding forward when the carriage already
started to print the next pass.
11.2.5. UV Options:
See chapter “6.2. Curing setup and sequences”, for detailed info.
11.2.6. Head Gap Control:
See chapter “10.1. Automatic “Head Base Height” Setup”, for detailed info.
11.2.7. Factory Set:
This button is password protected.
It can only be used by an Agfa trained technician.
11.2.8. Head Offset:
These are the Head alignment settings for each head, in reference to
the Black head. This alignment is done in advance by an engineer,
do NOT change these values!