Agilent Technologies 6683A, 6684A Fp Rom, EE Chksm, PRI Xram, PRI Iram, E6 PRI ROM, Gpib, Sec Ram

Models: 6682A 6680A 6681A 6683A 6684A

1 156
Download 156 pages 32.3 Kb
Page 32
Image 32

Table 3-2. Selftest Error Codes/Messages

 

Code and/or

Description

Probable Cause Selftest Error

 

Message

 

Codes/Messages

El FP RAM

Front panel RAM test failed (power-on).

Microprocessor AlU3

E2

FP ROM

Front panel ROM test failed (power-on

ROM AlU4 or address latches AlU8

 

 

and *TST?).

 

E3

EE CHKSM

Front panel EEPROM checksum test failed

Possibly due to power loss during a write

 

 

(power-on and *TST?).

operation. See Checksum Errors in Chapter 3 of

 

 

 

Operating Manual. If power loss is not the problem,

 

 

 

EEPROM A1U6 could be defective. (If you replace

 

 

 

AlU6, the power supply must be reinitialized and

 

 

 

calibrated.)

E4

PRI XRAM

Primary interface external RAM test failed

RAM A2U108

 

 

(power-on).

 

E5

PRI IRAM

Primary interface internal RAM test failed

Microprocessor A2U114

 

 

(power-on).

 

E6 PRI ROM

Primary interface ROM test failed

ROM A2U106

 

 

(power-on and *TST?).

 

E7

GPIB

GPIB interface test failed (power-on).

Talker/listener A2U117

E8

SEC RAM

Secondary interface RAM test failed

Microprocessor Al0U506

 

 

(power-on).

 

E9

SEC ROM

Secondary interface ROM test failed

Microprocessor Al0U506

 

 

(power-on and *TST?).

 

E10 SEC 5V

Secondary interface 5 volt readback test

Comparators Al0U516, Al0U517 readback DAC

 

 

failed (power-on and *TST?).

A10U512/U515, or secondary bias supply (5Vs

 

 

 

A4U304)

E11 TEMP

Ambient temperature readback test failed

Thermistor Al0RT500 or comparator

 

 

(power-on and *TST?).

Al0U517

E12 DACS

CV or CC DAC tests failed (power-on).

CV DAC Al0U510/U513 or CC DAC

 

 

 

A10U511/U514 (see Figure 3-7).

NOTE: The following error messages can appear due to a failure occurring either while the power supply is operating or during selftest.

SERIAL TIMOUT

Serial data line failure on A2 board.

See Figure 3-10 (system) or Figure 3-11 (bench).

SERIAL DOWN

Serial data line failure on A2 board.

See Figure 3-10 (system) or Figure 3-11 (bench).

UART PARITY

UART failed.

UART A2U112

UART FRAMING

UART failed.

UART A2U112

UART OVERRUN

UART failed.

UART A2U112

SBUF OVERRUN

Serial buffer failure UART.

UART A2U112 defective or GPIB board is in SA

 

 

mode

SBUF FULL

Serial buffer failure.

UART A2U112 defective or GPIB board is in SA

 

 

mode

EE WRITE ERR

EEPROM write failure.

EEPROM AlU6 defective or calibration error

SECONDARY DN

Serial data line failure on Main board.

See Figure 3-12.

Troubleshooting 33

Page 32
Image 32
Agilent Technologies 6683A Fp Rom, EE Chksm, PRI Xram, PRI Iram, E6 PRI ROM, Gpib, Sec Ram, Sec Rom, E11 Temp, E12 Dacs