Agilent Technologies 6814B, 6834B, 6843A manual Output VA Capability, 3.AC Source VA Capabilities

Models: 6834B 6843A 6814B

1 79
Download 79 pages 6.57 Kb
Page 13
Image 13
Output VA Capability

General Information - 1

Vrms

 

 

300 V

 

 

150 V

 

 

See Figure 1-3

 

 

0

 

Irms

10A (6834B 3phase)

5A

15A

30A

(6834B 1phase)

10A

20A

(6814B)

16A

32A

(6843A)

Figure 1-2. AC Source Output Characteristic (in real-time mode)

Output VA Capability

The output capability of each output phase is limited by VA (volts-amps) rather than power (watts). The amount of VA available to a load can be determined by examining figure 1-3, the output power curve. This curve rates the available VA versus output voltage. Full VA is available only at a full-scale voltage. Full current is available at voltages between 50% and 100% of the output voltage range. Appendix A documents the ac source’s specifications and supplemental characteristics.

NOTE: The load on the ac source may draw full VA at any power factor between 0 and 1, and may draw maximum current with a crest factor of 4 (3 for Agilent 6843A). If the load draws current in excess of the maximum rated rms or peak current, the voltage amplitude will be clipped to prevent excessive internal power dissipation.

 

100

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

MAXIMUM

80

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

OF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERCENT

50

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

VA,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

30

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

0

20

30

40

50

60

70

80

90

100

 

10

OUTPUT VOLTAGE, PERCENT OF RANGE

Figure 1-3. AC Source VA Capabilities

13

Page 13
Image 13
Agilent Technologies 6814B, 6834B, 6843A manual Output VA Capability, 3.AC Source VA Capabilities