Agilent Technologies 6834B manual Output Control Keys, Front Panel Operation, Display, Measurement

Models: 6834B 6843A 6814B

1 79
Download 79 pages 6.57 Kb
Page 36
Image 36
Output Control Keys

4 - Front Panel Operation

Shift

 

Harmonic

 

 

 

Press this key to access the harmonic menu list

Display

<reading>A I:MAG: <index>

<reading>° I:PHASE: <index>

<reading>V V:MAG: <index>

<reading>° V:PHASE: <index>

<reading> N:MAG: <index>

<reading>° N:PHASE: <index> <reading>° CURR:THD <reading>° VOLT:THD

Measurement

current harmonic magnitude current harmonic phase voltage harmonic magnitude voltage harmonic phase

neutral current harmonic magnitude neutral current harmonic phase current total % harmonic distortion voltage total % harmonic distortion

Output Control Keys

Output control keys control the output functions of the ac source.

Voltage

Press this key to access the voltage menu list.

Display

VOLT <value>

VOLT:T<value>

VOLT:M <char>

RANGE <char>

SLEW <value>

SLEW:T<value>

SLEW:M <char>

ALC <char>

Command Function

Set immediate rms output voltage (φ) Set triggered rms output voltage (φ)

Select the voltage mode (φ) (FIXED, STEP, PULSE or LIST) Select the voltage range (φ) (150 or 300)

Set immediate voltage slew rate in volts/second (φ) Set triggered voltage slew rate in volts/second (φ)

Select the voltage slew mode (φ) (FIXED, STEP, PULSE or LIST) Select the voltage sense source (INT or EXT)

Shift

Current

Press this key to access the current menu list.

Display

Command Function

CURR:LEV <value>

Set immediate rms output current limit

Freq

Press this key to access the frequency menu list.

Display

Command Function

FREQ <value>

Set immediate output frequency

FREQ:T<value>

Set triggered output frequency

FREQ:M <char>

Select the frequency mode (FIXED, STEP, PULSE or LIST)

SLEW <value>

Set immediate frequency slew rate in volts/second

SLEW:T<value>

Set triggered frequency slew rate in volts/second

SLEW:M <char>

Select the frequency slew mode (FIXED, STEP, PULSE or LIST)

Notes:

 

φ = phase selectable on Agilent 6834B reading = the returned measurement

index = a numeric value that represents the harmonic number from 0 to 50

char = a character string parameter

 

 

and

q

scroll through the command list.

Ø

 

￿

 

 

and

 

 

scroll through the parameter list.

pIndex

 

and

qIndex

specify the desired harmonic.

36

Page 36
Image 36
Agilent Technologies 6834B, 6814B, 6843A Output Control Keys, Front Panel Operation, Display, Measurement, Command Function