Agilent Technologies 6834B Specifications A, Table A-2.Supplemental Characteristicscontinued

Models: 6834B 6843A 6814B

1 79
Download 79 pages 6.57 Kb
Page 57
Image 57
Specifications A

Specifications A

Table A-2. Supplemental Characteristics (continued)

Parameter

INH/FLT Characteristics

Maximum Ratings:

INH Terminals:

FLT Terminals:

Saveable Data (nonvolatile)

Instrument States:

User-defined waveforms:

List Data:

GPIB Interface Capabilities

Language:

Interface:

Programming Time:

Recommended Calibration Interval:

Regulatory Compliance

Listed to:

Certified to:

Conforms to:

RFI Suppression

Complies with:

Dimensions

Height (add 12.7 mm or 0.5 in. for feet)

Width:

Depth:

Net Weight:

Shipping Weight:

Agilent 6814B

Agilent 6834B

Agilent 6843A

16.5Vdc between INH terminals; FLT terminals; and from INH terminals to chassis ground

Iol = 1.25 mA max. Vol = 0.5 Vmax. Vil = 0.8 V max. Vih = 2 V min. tw = 100 μs min.

td = 4 ms typical

16 (0 to 15)

12 (with 1024 data points in each)

1 to 100 points (for each list function)

SCPI, Elgar 9012 PIP

AH1, C0, DC1, DT1, E2, LE1, PP0, RL1, SH1, SR1, TE6

10ms 1 year

UL 3111-1

CSA 22.2 No. 1010-1

IEC 1010

CISPR-11, Group 1, Class A

 

 

262.6 mm (10.3 in.)

 

 

430.8 mm (16.96 in.)

 

 

 

602 mm (23.7 in.)

 

79.5 kg (175 lb)

 

87.7 kg (193 lb)

87.7 kg (193 lb)

119.1 kg (626 lb)

 

127.3 kg (280 lb)

127.3 kg (280 lb)

57

Page 57
Image 57
Agilent Technologies 6834B, 6814B, 6843A manual Specifications A, Table A-2.Supplemental Characteristicscontinued