8 – Language Dictionary
112
Command Syntax OUTPut:COMPensation:MODE <setting>
Parameters LLOCAL | LREMOTE | RLOCAL | RREMOTE
*RST Value LLOCAL
Examples OUTP:COMP:MODE HREMOTE
Query Syntax OUTPput:COMPensation:MODE?
Returned Parameters <CRD>
Backward Compatibility
(Agilent 66311B/D, 66309B/D) OUTP:TYPE[:CAPacitance] (LOW mode corresponds to
LLocal; HIGH mode corresponds to HRemote)
OUTPut:DFI
This command enables or disables the discrete fault indicator (DFI) output from the dc source.
Command Syntax OUTPut:DFI[:STATe] <bool>
Parameters 0 | 1 | OFF | ON
*RST Value OFF
Examples OUTP:DFI 1 OUTP:DFI ON
Query Syntax OUTPut:DFI[:STATe]?
Returned Parameters 0 | 1
Related Commands OUTP:DFI:SOUR
OUTPut:DFI:SOURce
This command selects the source for discrete fault indicator (DFI) events. The choices are:
QUEStionable selects the Questionable event summary bit (bit 3 of the Status Byte Register)
OPERation selects the Operation Event summary bit (bit 7 of the Status Byte Register)
ESB selects the Standard Event summary bit (bit 5 of the Status Byte Register)
RQS selects the Request Service bit (bit 6 of the Status Byte Register)
OFF selects no DFI source
Command Syntax OUTP:DFI:SOUR <source>
Parameters QUES | OPER | ESB | RQS | OFF
*RST Value OFF
Examples OUTP:DFI:SOUR OPER
Query Syntax OUTPut:DFI:SOUR?
Returned Parameters <CRD>
Related Commands OUTP:DFI
OUTPut:PON:STATe
This command selects the power-on state of the dc source. This information is saved in non-volatile
memory. The following states can be selected:
RST Sets the power-on state to *RST. Refer to *RST for more information.
RCL0 Sets the power-on state to *RCL 0. Refer to *RCL for more information.
Command Syntax OUTPut:PON:STATe <state>
Parameters RST | RCL0
Examples OUTP:PON:STAT RST
Query Syntax OUTPut:PON:STATe?
Returned Parameters <CRD>
Related Commands *RST *RCL