Agilent Technologies E1470A user manual Table B-10. Writing to Relay Control Registers

Models: E1470A

1 58
Download 58 pages 63.08 Kb
Page 48
Image 48

Table B-10. Writing to Relay Control Registers

To connect CH000 to:

COM00

COM01

COM02

COM03

COM04

COM05

COM25

 

 

 

 

 

 

 

 

Write to register 20h

0

132

2244

-29500

-13116

-13116

-13116

 

 

 

 

 

 

 

 

Write to register 28h

x

x

x

x

4

38

-32714

 

 

 

 

 

 

 

 

To connect CH001 to:

COM00

COM01

COM02

COM03

COM04

COM05

COM25

 

 

 

 

 

 

 

 

Write to register 20h

1

133

2245

-29499

-13115

-13115

-13115

 

 

 

 

 

 

 

 

Write to register 28h

x

x

x

x

4

38

-32714

 

 

 

 

 

 

 

 

To connect CH002 to:

COM00

COM01

COM02

COM03

COM04

COM05

COM25

 

 

 

 

 

 

 

 

Write to register 20h

2

134

2246

-29498

-13114

-13114

-13114

 

 

 

 

 

 

 

 

Write to register 28h

x

x

x

x

4

38

-32714

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To connect CH010 to:

COM01

COM02

COM03

COM04

COM05

COM25

 

 

 

 

 

 

 

 

 

Write to register 20h

0

2112

-29632

-13248

-13248

-13248

 

 

 

 

 

 

 

 

 

Write to register 28h

x

x

x

4

38

-32714

 

 

 

 

 

 

 

 

 

To connect CH011 to:

COM01

COM02

COM03

COM04

COM05

COM25

 

 

 

 

 

 

 

 

 

Write to register 20h

16

2128

-29616

-13232

-13232

-13232

 

 

 

 

 

 

 

 

 

Write to register 28h

x

x

x

4

38

-32714

 

 

 

 

 

 

 

 

 

To connect CH012 to:

COM01

COM02

COM03

COM04

COM05

COM25

 

 

 

 

 

 

 

 

 

Write to register 20h

32

2144

-29600

-13216

-13216

-13216

 

 

 

 

 

 

 

 

 

Write to register 28h

x

x

x

4

38

-32714

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To connect CH030 to:

COM03

COM03

COM05

COM25

 

 

 

 

 

 

 

 

 

 

 

Write to register 20h

0

16384

16384

16384

 

 

 

 

 

 

 

 

 

 

 

Write to register 28h

x

4

38

-32714

 

 

 

 

 

 

 

 

 

 

 

To connect CH031 to:

COM03

COM03

COM05

COM25

 

 

 

 

 

 

 

 

 

 

 

Write to register 20h

4096

20480

20480

20480

 

 

 

 

 

 

 

 

 

 

 

Write to register 28h

x

4

38

-32714

 

 

 

 

 

 

 

 

 

 

 

To connect CH032 to:

COM03

COM03

COM05

COM25

 

 

 

 

 

 

 

 

 

 

 

Write to register 20h

8192

24576

24576

24576

 

 

 

 

 

 

 

 

 

 

 

Write to register 28h

x

4

38

-32714

 

 

 

 

 

 

 

 

 

 

 

48 Register-Based Programming

Appendix B

Page 48
Image 48
Agilent Technologies E1470A user manual Table B-10. Writing to Relay Control Registers