MAINTENANCE
Reservoir
The reservoir stores hydraulic system oil. The breather cap which is mounted on top of the reservoir prevents a pressure buildup or vacuum from occurring in the tank as oil level changes. Their is also an oil filler cap which is used to fill the reservoir with oil. To help prevent dirt from entering the tank, clean the top of the reservoir before removing the cap. THE BREATHER CAP HOLDS APPROX 11 PSI PRESSURE IN TANK.
REMOVE FILLER CAP SLOWLY
Air Breather
Cap
Filler Cap
The oil level sight glass is located on the back of the reservoir. The oil level should be even with the sight glass and checked with the cutter unit in the transport position. The oil temperature should not exceed 180 deg.F.
The oil return hoses are connected to the hydraulic filter on top of the reservoir. Oil is returned from cutter unit cooling tubes and filtered before entering the hydraulic reservoir. Oil returning from the control circuit also enters the reservoir thru the filter. Use Chevron 1000THF or an equivalent.
Note: Your ambient temperature and operating con ditions may require a different viscosity oil. Please consult the oil manufacturer for proper specifications.
Solenoid Control Valve
The solenoid control valve directs oil flow from the hydraulic pump. When the mower ON/OFF switch is in the "ON" position, the solenoid is energized and the spool within the valve is positioned to direct oil to the cuttershaft motor.
When the mower ON/OFF switch is in the "OFF" position, oil pressure within the valve pushes the spool back which allows the oil to circulate through the cutter unit before returning to the reservoir. When the flow of oil to the motor is cut off, the cuttershaft will stop rotating. Figure
a. Control Valve b. Solenoid
INTERSTATER 03/09 | Maintenance Section |
© 2009 Alamo Group Inc.