MAINTENANCE
INTERSTATER 03/09 Maintenance Section 5-15
© 2009 Alamo Group Inc.
MAINTENANCE

Reservoir

The reservoir stores hydraulic system oil. The b reather ca p which is mounted on top of the reserv oir prevent s
a pressure buildup or vacuum from occurring in the tank as oil level changes. Their is also an oil filler cap
which is used to fill the reservoir with oil. To help prevent dirt from entering the tank, clean the top of the
reservoir before removing the cap. THE BREATHER CAP HOLDS APPROX 11 PSI PRESSURE IN TANK.
REMOVE FILLER CAP SLOWLY
The oil level sight glass is located on the back of the reservoir. The oil leve l should be even with the sight glass
and checked with the cutter unit in the transport position. The oil temp erature should not exceed 180 deg.F.
The oil return hoses ar e connected to the hydraulic filter on top of the reservoir . Oil is returned from cutter unit
cooling tubes and filtered before entering the hydraulic reservoir. Oil returning from the control circuit also
enters the reservoir thru the filter. Use Chevron 1000THF or an equivalent.
Note: Your ambient temperature and operating con ditions may require a different viscosity oil. Please consult
the oil manufacturer for proper specifications.

Solenoid Control Valve

The solenoid control valve directs oil flow from the
hydraulic pump. When the mower ON/OFF switch
is in the "ON" position, the solenoid is energized
and the spool within the valve is position ed to direct
oil to the cuttershaft motor.
When the mower ON/OFF switch is in the "OFF"
position, oil pressure within the valve pushes the
spool back which allows the oil to circulate through
the cutter unit before returning to the reservoir.
When the flow of oil to the motor is cut off, the
cuttershaft will stop rotating. Figure Mnt-FL-0017
Air Breather
Cap
Filler Cap
a. Control Valve
b. Solenoid