Remove all eight Bolts from Input Cap using a 14mm Socket. Then using a Hammer, tap the Output end of the Input Shaft. This will loosen the input Cap and allow the removal of the complete Input Shaft Assembly. FIGURE 30.

MAINTENANCE

STEP 5

Remove all eight Bolts from Input Cap using a 14mm Socket. Then using a Hammer, tap the Output end of the Input Shaft. This will loosen the input Cap and allow the removal of the complete Input Shaft Assembly. FIGURE 30.

FIGURE 30

STEP 6

The Input Gear and Bearing can be removed from the Input Shaft by tapping the end of the Input Shaft on a solid surface. FIGURE 31.

FIGURE 31

The unit is now completely disassembled with exception of Oil Seals and Bearing Races that can be removed by conventional means. FIGURE 32.

Inspect and replace all worn or defective parts.