Configuring IPMS on a Switch
Configuring IP Multicast Switching
page 26-6
OmniSwitch 6600 Family Network Configuration Guide
April 2006
Configuring a Static Neighbor
You can configure a port as an IPMS static neighbor port by entering
followed by the VLAN number (which must be between 0 and 4095), a space, the slot number of the port,
a slash (
/
), and the port number.
For example, to configure port 4 in slot 10 with designated VLAN 2 as a static neighbor you would enter:
-> ip multicast static-neighbor 2 4/10
You can also configure a link aggregation group as an IPMS static neighbor port by entering
followed by the VLAN number (which must be between 0 and 4095), a space,
linkagg
,
and the aggregation group number.
For example, to configure link aggregation group 7 with designated VLAN 2 as a static neighbor you
would enter:
-> ip multicast static-neighbor 2 linkagg 7
Removing a Static Neighbor
To reset the port so that it is no longer an IPMS static neighbor port you use the
no
form of the
command by entering
ip multicast no static-neighbor
followed by the
VLAN number, a space, and either the port (designate the slot number of the port, a slash (
/
), and the port
number) or
linkagg
and link aggregation group number.
For example, to remove port 4 in slot 10 with designated VLAN 2 as a static neighbor you would enter:
-> ip multicast no static-neighbor 2 4/10
Configuring and Removing a Static Querier
IPMS static querier ports receive IGMP reports generated on the designated VLAN. Unlike IPMS neigh-
bor ports, they will not receive all multicast streams. The following subsections describe how to configure
and remove a static querier with the
command.
Configuring a Static Querier
You can configure a port as an IPMS static querier port by entering
followed
by the VLAN number (which must be between 0 and 4095), a space, the slot number of the port, a slash
(
/
), and the port number.
For example, to configure port 4 in slot 10 with designated VLAN 2 as a static querier you would enter:
-> ip multicast static-querier 2 4/10
You can also configure a link aggregation group as an IPMS static querier port by entering
followed by the VLAN number (which must be between 0 and 4095), a space,
linkagg
, and
the link aggregation group number.
For example, to configure link aggregation group 7 with designated VLAN 2 as a static querier you would
enter:
-> ip multicast static-querier 2 linkagg 7