RIP Security
Configuring RIP
page 16-14
OmniSwitch 6600 Family Network Configuration Guide
April 2006
RIP Security
By default, there is no authentication used for a RIP. However, you can configure a password for a RIP
interface. To configure a password, you must first select the authentication type (simple or MD5), then
configure a password.
Configuring Authentication Type
If simple or MD5 password authentication is used, both switches on either end of a link must share the
same password. Use the
command to configure the authentication type. Enter
the IP address of the RIP interface, then enter an authentication type:
•
none.
No authentication will be used.
•
simple.
Simple password authentication will be used.
•
md5.
MD5 authentication will be used.
For example, to configure RIP interface 172.22.2.115 for simple authentication you would enter:
-> ip rip interface 172.22.2.115 auth-type simple
To configure RIP interface 172.22.2.115 for MD5 authentication you would enter:
-> ip rip interface 172.22.2.115 md5 auth-type md5