RIP Security

Configuring RIP

page 16-14

OmniSwitch 6600 Family Network Configuration Guide

April 2006

RIP Security

By default, there is no authentication used for a RIP. However, you can configure a password for a RIP 

interface. To configure a password, you must first select the authentication type (simple or MD5), then 

configure a password.

Configuring Authentication Type

If simple or MD5 password authentication is used, both switches on either end of a link must share the 

same password. Use the 

ip rip interface auth-type

 command to configure the authentication type. Enter 

the IP address of the RIP interface, then enter an authentication type: 

•

none. 

No authentication will be used. 

•

simple. 

Simple password authentication will be used. 

•

md5. 

MD5 authentication will be used.

For example, to configure RIP interface 172.22.2.115 for simple authentication you would enter:

-> ip rip interface 172.22.2.115 auth-type simple

To configure RIP interface 172.22.2.115 for MD5 authentication you would enter:

-> ip rip interface 172.22.2.115 md5 auth-type md5