Setting Ethernet Port Parameters

Configuring Ethernet Ports

page 1-24

OmniSwitch 6600 Family Network Configuration Guide

April 2006

As an option, you can document the interface type by entering 

ethernet

, 

fastethernet

, or 

gigaethernet

 

before the slot number. For example, to enable flow control on port 3 on slot 2 and document the port as 

Fast Ethernet enter:

-> interfaces fastethernet 2/3 flow enable

Note. 

If auto negotiation is disabled and then later enabled on an interface, the original flow setting will 

then be restored.