Setting Ethernet Port Parameters
Configuring Ethernet Ports
page 1-24
OmniSwitch 6600 Family Network Configuration Guide
April 2006
As an option, you can document the interface type by entering
ethernet
,
fastethernet
, or
gigaethernet
before the slot number. For example, to enable flow control on port 3 on slot 2 and document the port as
Fast Ethernet enter:
-> interfaces fastethernet 2/3 flow enable
Note.
If auto negotiation is disabled and then later enabled on an interface, the original flow setting will
then be restored.