Setting Ethernet Port Parameters Configuring Ethernet Ports
page 1-24 OmniSwitch 6600 Family Network Configuration Guide April 2006
As an option, you can document the interface type by entering ethernet, fastethernet, or gigaethernet
before the slot number. For example, to enable flow control on port 3 on slot 2 and document the port as
Fast Ethernet enter:
-> interfaces fastethernet 2/3 flow enable
Note. If auto negotiation is disabled and then later enabled on an interface, the original flow setting will
then be restored.