Setting Ethernet Port Parameters

Configuring Ethernet Ports

page 1-22

OmniSwitch 6600 Family Network Configuration Guide

April 2006

Configuring Auto Negotiation, Crossover, and Flow Control 

Settings

The following subsections describe how to enable and disable auto negotiation (see 

“Enabling and 

Disabling Auto Negotiation” on page 1-22

), configuring crossover settings (see 

“Configuring Crossover 

Settings” on page 1-23

), and configuring flow control (see 

“Enabling and Disabling Flow” on page 1-23

). 

Enabling and Disabling Auto Negotiation

By default, auto negotiation is enabled. To enable or disable auto negotiation on a single port, a range of 

ports, or an entire slot use the 

interfaces autoneg

 command. (See 

“Configuring Crossover Settings” on 

page 1-23

 and 

“Enabling and Disabling Flow” on page 1-23

 for more information).

To enable or disable auto negotiation on an entire switch enter 

interfaces

 followed by the slot number, 

autoneg

, and either 

enable

 or 

disable

. For example, to enable auto negotiation on slot 2 enter:

-> interfaces 2 autoneg enable

To enable or disable auto negotiation on a single port enter 

interfaces

 followed by the slot number, a slash 

(

/

), the port number, 

autoneg

, and either 

enable

 or 

disable

. For example, to enable auto negotiation on 

port 3 on slot 2 enter:

-> interfaces 2/3 autoneg enable

To enable or disable auto negotiation on a range of ports enter 

interfaces

 followed by the slot number, a 

slash (

/

), the first port number, a hyphen (-), the last port number, 

autoneg

, and either 

enable

 or 

disable

. 

For example, to enable auto negotiation on ports 1 through 3 on slot 2 enter:

-> interfaces 2/1-3 autoneg enable

As an option, you can document the interface type by entering 

ethernet

, 

fastethernet

, or 

gigaethernet

 

before the slot number. For example, to enable auto negotiation on port 3 on slot 2 and document the port 

as Ethernet enter:

-> interfaces ethernet 2/3 autoneg enable

Please note a link will not be established on any copper Ethernet port if any one of the following is true:

•

The local port advertises 100 Mbps full duplex and the remote link partner is forced to 100 Mbps full 

duplex.

•

The local port advertises 100 Mbps full duplex and the remote link partner is forced to 100 Mbps half 

duplex.

•

The local port advertises 10 Mbps full duplex and the remote link partner is forced to 10 Mbps full 

duplex.

•

The local port advertises 10 Mbps full duplex and the remote link partner is forced to 10 half duplex.

This is due to the fact that when the local device is set to auto negotiating 10/100 full duplex it senses the 

remote device is not auto negotiating. Therefore it resolves to Parallel Detect with Highest Common 

Denominator (HCD), which is “10/100 Half” according to IEEE 802.3 Clause 28.2.3.1.

However, since the local device is set to auto negotiating at 10/100 full duplex it cannot form a 10/100 

Mbps half duplex link in any of the above mentioned cases. One solution is to configure the local device to 

auto negotiation, 10/100 Mbps, with auto or half duplex.