Configuring QoS

Configuring Global QoS Parameters

OmniSwitch 6600 Family Network Configuration Guide

April 2006

page 24-15

Note. 

If you change the number of log lines, the QoS log may be completely cleared. To change the log 

lines without clearing the log, set the log lines in the 

boot.cfg

 file; the log will be set to the specified 

number of lines at the next reboot.

Log Detail Level

To change the level of detail in the QoS log, use the 

qos log level

 command. The log level determines the 

amount of detail that will be given in the QoS log. The 

qos log level

 command is associated with the 

qos 

debug

 command, which determines what kind of information will be included in the log.

The default log level is 6. The range of values is 1 (lowest level of detail) to 9 (highest level of detail). For 

example:

-> qos log level 7

The log level is changed immediately but the setting is not saved in flash. To activate the change, enter the 

qos apply

 command. For more information about the 

qos apply

 command, see 

“Applying the Configura-

tion” on page 24-46

.

Note. 

A high log level value will impact the performance of the switch.

Forwarding Log Events to PolicyView

In addition to managing policies created directly on the switch, the switch manages policies downloaded 

from an external LDAP server. These policies are created externally through the PolicyView NMS appli-

cation. PolicyView may query the switch for logged QoS events. Use the 

qos forward log

 command to 

make QoS log events available to PolicyView in real time. For example:

-> qos forward log

To disable log forwarding, enter the following command:

-> qos no forward log

To activate the change, enter the 

qos apply

 command. For more information about the 

qos apply

 

command, see 

“Applying the Configuration” on page 24-46

.

If event forwarding is disabled, PolicyView will still be able to query the QoS software for events, but the 

events will not be sent in real time.

Forwarding Log Events to the Console

QoS log messages may be sent to a console attached directly to the switch. By default, QoS log messages 

are not sent to the console. To send log events to the console, enter the following command:

-> qos log console

To disable immediate forwarding of events to the console, enter the following command:

-> qos no log console

To activate the change, enter the 

qos apply

 command. For more information about the 

qos apply

 

command, see 

“Applying the Configuration” on page 24-46

.

Page 495
Image 495