Monitoring Switch Health

Diagnosing Switch Problems

page 27-36

OmniSwitch 6600 Family Network Configuration Guide

April 2006

Configuring Sampling Intervals

The 

sampling interval

 is the period of time between polls of the switch’s consumable resources to moni-

tor performance vis-a-vis previously specified thresholds. The 

health interval

 command can be used to 

configure the sampling interval between health statistics checks. 

To configure the sampling interval, enter the 

health interval

 command, followed by the number of 

seconds.

For example, to specify a 

sampling interval 

value of 6 seconds, enter the following command:

-> health interval 6

Valid values for the seconds parameter include 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, or 30.

Note. 

If the sampling interval is decreased, switch performance may be affected.

Viewing Sampling Intervals

The 

show health interval

 command can be used to display the current health sampling interval (period of 

time between health statistics checks), measured in seconds. 

To view the sampling interval, enter the 

show health interval

 command. The currently configured health 

sampling interval (measured in seconds) will be displayed, as shown below:

-> show health interval

Sampling Interval = 5