Quick Steps for Configuring Switch Logging

Using Switch Logging

page 28-4

OmniSwitch 6600 Family Network Configuration Guide

April 2006

Quick Steps for Configuring Switch Logging

1

Enable switch logging by using the following command:

-> swlog

2

Specify the ID of the application to be logged along with the logging severity level. 

-> swlog appid bridge level warning

Here, the application ID specifies bridging and the severity is set to the “warning” level.

3

Specify the output device to which the switch logging information will be sent.

-> swlog output console

In this example, the switch logging information will be sent to the console port.

Note. 

Optional. 

To verify the switch logging configuration, enter the 

show swlog 

command. The display 

is similar to the one shown below:

Switch Logging is:

- INITIALIZED

- RUNNING

Log Device(s)

----------------

flash

console

Only Applications not at the level ‘info’ (6) are shown

Application ID

Level

----------------------------

BRIDGE(10)

warning (5)

For more information about this command, or the “Switch Logging Commands” chapter in the 

OmniSwitch CLI Reference Guide

.

Page 612