Using Switch Logging

Switch Logging Commands Overview

OmniSwitch 6600 Family Network Configuration Guide

April 2006

page 28-11

Configuring the Switch Logging File Size

By default, the size of the switch logging file is 128000 bytes. To configure the size of the switch logging 

file use the 

swlog output flash file-size

 command. To use this command enter 

swlog output flash file 

size

 followed by the number of bytes, which must be at least 32000. (The maximum size the file can be is 

dependent on the amount of free memory available in flash memory.)

Note. 

Use the 

ls

 command, which is described in the 

OmniSwitch 6600 Family

 

Switch Management 

Guide

, to determine the amount of available flash memory.

For example, to set the switch logging file to 500000 bytes enter:

-> swlog output flash file-size 500000

Clearing the Switch Logging Files

You can clear the data stored in the switch logging files by executing the following command:

-> swlog clear

This command will cause the switch to clear all the switch logging information and begin recording again. 

As a result, the switch will display a shorter file when you execute the 

show log swlog

 command. You 

may want to use 

swlog clear

 when the switch logging display is too long due to some of the data being old 

or out dated. 

No confirmation message will appear on the screen.