Configuring Access Guardian Policies

Configuring 802.1X

page 22-18

OmniSwitch 6600 Family Network Configuration Guide

April 2006

802.1x 2/10 non-supplicant policy authentication 

pass vlan 10 block fail group-mobility default-vlan 

If the MAC authentication process is successful 

but does not return a VLAN ID for the device, then 

the following occurs:

1

The device is assigned to VLAN 10.

2

If VLAN 10 does not exist, then the device is 

blocked from accessing the switch on port 

2/10.

If the device fails MAC authentication, then the 

following occurs:

1

Group Mobility rules are applied.

2

If Group Mobility classification fails, then the 

device is assigned to the default VLAN for 

port 2/10.

3

If the default VLAN for port 2/10 is an authen-

ticated VLAN, then the device is blocked from 

accessing the switch on port 2/10.

802.1x 3/1 non-supplicant policy authentication 

pass vlan 10 block fail group-mobility vlan 43 

default-vlan

If the MAC authentication process is successful 

but does not return a VLAN ID for the device, then 

the following occurs:

1

The device is assigned to VLAN 10.

2

If VLAN 10 does not exist, then the device is 

blocked from accessing the switch on port 3/1.

If the device fails MAC authentication, then the 

following occurs:

1

Group Mobility rules are applied.

2

If Group Mobility classification fails, then the 

device is assigned to VLAN 43.

3

If VLAN 43 does not exist or is an authenti-

cated VLAN, then the device is assigned to the 

default VLAN for port 3/1.

4

If the default VLAN for port 3/1 is an authenti-

cated VLAN, then the device is blocked from 

accessing the switch on port 3/1.

802.1x 3/10 non-supplicant policy vlan 43 block

No authentication process is performed.but the fol-

lowing classification still occurs:

1

If VLAN 43 exists and is not an authenticated 

VLAN, then the device is assigned to 

VLAN 43.

2

If VLAN 43 does not exist or is an authenti-

cated VLAN, then the device is blocked from 

accessing the switch on port 3/10.

Supplicant Policy Command Example

 Description

Page 470
Image 470
Open full-size image