Alliance Laundry Systems PHM802N, PHM798N manual Mounting Bolt Installation Requirements

Models: PHM798N PHM802N

1 61
Download 61 pages 41.51 Kb
Page 32
Image 32

Specifications and Dimensions

Mounting Bolt Installation

Requirements

Approved Foundations Only

NOTE: If installing expansion bolts into an elevated concrete foundation pad, the concrete foundation pad should extend a minimum of 9 inches (229 mm) for 35 machines or 12 inches (305

mm)for 60 - 150 machines out from the machine base on all sides. Refer to Figure 9.

A bolt kit consisting of eight bolts is available as an option. 35 machines use 5/8-11 x 8 inch bolts.

60 – 125 machines use 3/4-10 x 8 inch bolts. 150 machines use 3/4-10 x 10 inch grade 5 bolts. The bolts should be embedded in a 3500 psi (241 bar) minimum reinforced concrete floor that is a minimum of 6 inches (153 mm) (for 35 and 60 2-speed, L-speed, and M-speed models) or a 12 inch (305 mm) (for all other models) thick. Use the mounting bolt layouts in Mounting Bolt Hole Locations section.

On 35 – 125 machines, the threaded end of the bolts should extend 2 inches (5.08 cm) above the mounting surface. On 150 machines, the threaded end of the bolts should extend 3 inches above the mounting surface.

Refer to Figure 10 for a typical installation of individual mounting bolts.

1

0.75 in.2

(19 mm)

2 in.

3

(51 mm)

 

8 in.

4

(203 mm)

For new foundations a bolt-locator fixture or rebar frame is available and a preferred option. This rigid welded assembly made of reinforcing rod and mounting bolts is designed to be embedded in concrete. Refer to Figure 11.

1

2

3

4

PHM179N

1Machine Frame Base

2Mounting Bolt Threads

3Grouting

4Reinforcing Rod

Figure 11

PHM722N

1Machine Frame Base

2Mounting Bolt Threads

3Grouting

4Cement or Structural Epoxy

Figure 10

30

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Page 32
Image 32
Alliance Laundry Systems PHM802N, PHM798N manual Mounting Bolt Installation Requirements, Specifications and Dimensions