Chemical injection Using External AC Power Source

NOTE: An External AC Power Source is NOT provided by Alliance Laundry Systems.

NOTE: Power for external supplies must not be derived from the high-voltage main power connection point.

Specifications and Dimensions

IMPORTANT: The external power must supply power of 240VAC or less and be protected at 3 Amps or less.

1.Remove the red jumper wire installed by the factory between “24VAC”: and “RELAY COM”.

2.Connect one side of the external power to the “RELAY COM” and the other to the external dispenser input signals common. Refer to Figure 32.

 

 

 

3

 

1

 

 

 

 

 

4

 

 

2

 

 

 

 

= Neutral

 

 

 

= Power

 

 

 

5

 

 

 

PHM823N

1

External Supply Power

4

VAC Power Terminal

2

Red Jumper Wire

5

VAC RETURN Terminal

3

External Supply Common

 

 

Figure 32

CAUTION

Do not attempt to increase fuse rating or alter wiring of external chemical supply terminal strip in such as way that may conflict with the suggested methods provided on the Optional External Supply Wiring Diagram.

W699

F8138601

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT