Alliance Laundry Systems PHM802N, PHM798N manual Med

Models: PHM798N PHM802N

1 61
Download 61 pages 41.51 Kb
Page 16
Image 16

Specifications and Dimensions

UWL, UWN and UWU Models Starting 4/1/09 (Continued)

Specifications

35

60

80

100

125

150

 

 

 

 

 

 

 

Cylinder Speeds / Centrifugal Force Data

 

 

 

 

 

 

 

 

 

 

 

1/2 Wash/reverse, rpm (g)

26 (.25)

26 (.31)

26 (.35)

26 (.35)

26 (.40)

23 (.32)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Wash/reverse, rpm (g)

44 (.73)

42 (.66)

40 (0.8)

40 (0.8)

37 (0.8)

36 (0.8)

 

 

 

 

 

 

 

Distribution, rpm (g)

83 (2.57)

74 (2)

70 (2.50)

70 (2.50)

62 (2.29)

61 (2.29)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Very Low extract, rpm (g)

401 (60)

364 (60)

343 (60)

343 (60)

317 (60)

314 (60)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Low extract rpm (g)

568 (120)

514 (120)

485 (120)

485 (120)

449 (120)

444 (120)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium extract, rpm (g)

695 (180)

630 (180)

594 (180)

594 (180)

550 (180)

543 (180)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

High extract, rpm (g)

803 (240)

727 (240)

686 (240)

686 (240)

565 (190)

627 (240)

 

(Variable-speed

(Variable-speed

 

 

 

 

 

models)

models)

 

 

 

 

 

492 (90)

482 (106)

 

 

 

 

 

(2-speed models)

(2-speed models)

 

 

 

 

 

 

 

 

 

 

 

Very High extract, rpm (g)

898 (300)

813 (300)

766 (300)

766 (300)

579 (200)

701 (300)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Balance Detection

 

 

 

 

 

 

Vibration switch installed

STD (Variable-

speed models)

N/A (2-speed

models)

STD (Variable-

speed models)

N/A (2-speed

models)

STD

STD

STD

STD

Direct Steam Heating (Optional)

Steam inlet connection size,

0.5 (13)

0.5 (13)

0.5 (13)

0.5 (13)

0.75 (19)

0.75 (19)

in. (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of steam inlets

 

1

1

1

1

1

1

 

 

 

 

 

 

 

 

Steam required to

LOW

2.1 (1.5)

3.3 (2.4)

4.6 (3.3)

5.7 (4.1)

6.7 (4.9)

8.3 (6.0)

raise bath temperature

 

 

 

 

 

 

 

MED

2.3 (1.7)

3.7 (2.6)

5.2 (3.8)

6.5 (4.7)

7.8 (5.6)

9.5 (6.9)

10°F, lb. (10°C, kg)

 

 

 

 

 

 

 

 

 

HIGH

2.7 (1.9)

4.1 (2.9)

6.1 (4.4)

7.6 (5.5)

9.1 (6.6)

11.1 (8.0)

 

 

 

 

 

 

 

 

Average consumption per

1.4 (21.4)

2.1 (33.4)

3.1 (48.4)

3.8 (60.4)

4.6 (72.0)

5.8 (91.0)

cycle, BHP (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

Total

200V

10.8

19.1

28.6

28.6

N/A

N/A

electrical heating

 

 

 

 

 

 

 

240V

15.6

27.4

41.2

41.2

N/A

N/A

capacity,

kW (N/A for 2 speed

 

 

 

 

 

 

 

380V

9.8

17.2

17.2

17.2

34.4

N/A

models)

 

 

 

 

 

 

 

 

 

415V

11.7

20.5

20.5

20.5

41.0

N/A

 

 

 

 

 

 

 

 

 

480V

15.6

27.4

27.4

27.4

54.8

N/A

 

 

 

 

 

 

 

 

Number of electrical heating

6

6

9

9

12

N/A

elements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical heating element size,

2.6

4.2

4.2

4.2

4.2

N/A

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Page 16
Image 16
Alliance Laundry Systems PHM802N, PHM798N manual Med