Specifications and Dimensions

Floor Load Data

Static and dynamic loads on the floor or foundation are shown in Table 4 and Table 5.

UWTV Pocket Hardmount Floor Load Data (Models Through 3/31/09)

Specifications

Design

35

60

 

80

100

125

150

Series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Static floor load, lbs (kN)

U1 and

1272 (5.66)

1677 (7.45)

2292 (10.2)

2490 (11.1)

3283 (14.6)

3936

(17.5)

 

greater

 

 

 

 

 

 

 

 

Static pressure,

U1 and

169 (8.08)

187 (8.94)

184

(8.79)

199 (9.6)

205 (9.8)

202

(9.7)

lbs/ft2

greater

 

 

 

 

 

 

 

 

Dynamic floor load, lbs (kN)

U1 and

1648 (7.33)

2824 (12.6)

3679

(16.36)

3690 (16.41)

5011 (22.29)

4358

(19.4)

 

greater

 

 

 

 

 

 

 

 

Dynamic pressure,

U1 and

219 (10.5)

317 (15.2)

295

(14.2)

295 (14.2)

312 (15)

224 (11)

lbs/ft2 (kN/m2)

greater

 

 

 

 

 

 

 

 

Dynamic load frequency, Hz

U1 and

15

13.6

12.8

12.8

9.7

11.7

 

greater

 

 

 

 

 

 

 

 

1Maximum vertical load,

U1 and

2719 (12.1)

4168 (18.5)

5482

(24.38)

5561 (24.73)

7559 (33.62)

7508

(33.4)

lbs (kN)

greater

 

 

 

 

 

 

 

 

2Minimum vertical load,

U1 and

576 (2.56)

1450 (6.45)

1852 (8.24)

1794 (8.0)

2434 (10.8)

1208 (5.4)

lbs (kN)

greater

 

 

 

 

 

 

 

 

Base moment, lb/ft (kN/m)

U1 and

4249 (5.8)

8895 (12.1)

11951 (16.2)

11984 (16.3)

16606 (22.5)

16707 (22.7)

 

greater

 

 

 

 

 

 

 

 

1Acting in the downward direction against the floor.

2Acting in the upward direction away from the floor.

Table 4