Specifications and Dimensions
Floor Load Data
Static and dynamic loads on the floor or foundation are shown in Table 4 and Table 5.
UWTV Pocket Hardmount Floor Load Data (Models Through 3/31/09)
Specifications | Design | 35 | 60 |
| 80 | 100 | 125 | 150 | |
Series |
| ||||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Static floor load, lbs (kN) | U1 and | 1272 (5.66) | 1677 (7.45) | 2292 (10.2) | 2490 (11.1) | 3283 (14.6) | 3936 | (17.5) | |
| greater |
|
|
|
|
|
|
|
|
Static pressure, | U1 and | 169 (8.08) | 187 (8.94) | 184 | (8.79) | 199 (9.6) | 205 (9.8) | 202 | (9.7) |
lbs/ft2 | greater |
|
|
|
|
|
|
|
|
Dynamic floor load, lbs (kN) | U1 and | 1648 (7.33) | 2824 (12.6) | 3679 | (16.36) | 3690 (16.41) | 5011 (22.29) | 4358 | (19.4) |
| greater |
|
|
|
|
|
|
|
|
Dynamic pressure, | U1 and | 219 (10.5) | 317 (15.2) | 295 | (14.2) | 295 (14.2) | 312 (15) | 224 (11) | |
lbs/ft2 (kN/m2) | greater |
|
|
|
|
|
|
|
|
Dynamic load frequency, Hz | U1 and | 15 | 13.6 | 12.8 | 12.8 | 9.7 | 11.7 | ||
| greater |
|
|
|
|
|
|
|
|
1Maximum vertical load, | U1 and | 2719 (12.1) | 4168 (18.5) | 5482 | (24.38) | 5561 (24.73) | 7559 (33.62) | 7508 | (33.4) |
lbs (kN) | greater |
|
|
|
|
|
|
|
|
2Minimum vertical load, | U1 and | 576 (2.56) | 1450 (6.45) | 1852 (8.24) | 1794 (8.0) | 2434 (10.8) | 1208 (5.4) | ||
lbs (kN) | greater |
|
|
|
|
|
|
|
|
Base moment, lb/ft (kN/m) | U1 and | 4249 (5.8) | 8895 (12.1) | 11951 (16.2) | 11984 (16.3) | 16606 (22.5) | 16707 (22.7) | ||
| greater |
|
|
|
|
|
|
|
|
1Acting in the downward direction against the floor.
2Acting in the upward direction away from the floor.
Table 4
F8138601 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 27 |