Specifications and Dimensions

Chemical Injection Using Internal 24VAC Control Transformer

NOTE: Using the Internal 24VAC 300 Milliamp Control Transformer is recommended by Alliance Laundry Systems.

IMPORTANT: DO NOT remove the red jumper wire from the terminal strip.

There are 3 terminals necessary for this connection option.

Terminal “24VAC COM” is used to connect one side of the internal control transformer to the external dispenser input signals common.

The second terminal is used to connect the other side of the control transformer to the washer- extractor output signals common through a red jumper wire between “24VAC” and “RELAY COM”. Refer to Figure 31.

IMPORTANT: Do not use the transformer terminals if an external power supply is used.

 

 

 

3

 

 

2

 

 

 

 

4

 

 

 

5

 

1

 

 

 

 

 

6

 

 

 

= Neutral

 

 

7

= Power

 

 

 

 

 

 

PHM821N

1

External Supply Power

5

Red Jumper Wire

2

Internal Control Transformer

6

24VAC Terminal

3

RELAY COM Terminal

7

24VAC COM Terminal

4

External Supply Common

 

 

Figure 31

56

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Page 58
Image 58
Alliance Laundry Systems PHM802N, PHM798N manual Chemical Injection Using Internal 24VAC Control Transformer