Alliance Laundry Systems PHM802N, PHM798N manual Chemical Injection Supply System

Models: PHM798N PHM802N

1 61
Download 61 pages 41.51 Kb
Page 54
Image 54

Specifications and Dimensions

 

Chemical Injection Supply System

Undiluted chemical dripping can damage the washer-

 

 

 

 

extractor. Therefore, all chemical supply dispenser

 

 

 

WARNING

pumps should be mounted below the washer’s

 

 

 

injection point. All dispenser tubing should also run

Wear eye and hand protection when

below the injection point. Loops do not prevent drips

handling chemicals; always avoid direct

if these instructions are not followed. Failure to follow

contact with raw chemicals. Read the

these instructions could damage the machine and void

manufacturer’s directions for accidental

the warranty. Figure 27 shows a typical Chemical

contact before handling chemicals.

Injection Supply System.

Ensure an eye-rinse facility and an

 

emergency shower are within easy reach.

 

Check at regular intervals for chemical

 

leaks.

 

 

 

SW016

 

 

2

 

3

 

 

 

 

1

 

 

 

4

 

 

 

 

 

PHM825N

1

Injection Point

3

Chemical Dispenser Pump Outlet

2

Loops

4

PVC Pipe

Figure 27