Specifications and Dimensions

 

Voltage Designation

 

 

Non-Electric Heat

 

 

Electric Heat Machines

 

 

 

 

 

 

Machines (Standard)

 

 

 

 

Model

Code

Voltage

Cycle

Phase

Wire

FullLoad Amps

Breaker

*AWG

2

FullLoad Amps

Breaker

*AWG

2

 

 

 

 

 

 

 

 

 

*mm

 

 

 

*mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200 – 240

50/60

3

3

10

15

14

2.5

 

108

110

1

50

 

(Through

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4/13/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200 – 240

50/60

3

3

14

20

14

2.5

 

108

110

1

50

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4/14/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

380 – 480

50/60

3

3

10

15

14

2.5

 

40

50

6

16

100

(Through

 

 

 

 

 

 

 

 

 

 

 

 

 

10/1/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440 – 480

50/60

3

3

10

15

14

2.5

 

40

50

6

16

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380 – 415

50/60

3

3

10

15

14

2.5

 

40

50

6

16

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200 – 240

50/60

3

3

9

15

14

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

380 – 480

50/60

3

3

8

15

14

2.5

 

NOT AVAILABLE

 

 

(Through

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/1/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

125

N

440 – 480

50/60

3

3

8

15

14

2.5

 

74

80

4

25

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380 – 415

50/60

3

3

8

15

14

2.5

 

65

70

4

25

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200 – 240

50/60

3

3

16

20

12

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

380 – 480

50/60

3

3

11

15

14

2.5

 

 

 

 

 

 

(Through

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/1/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

150

N

440 – 480

50/60

3

3

11

15

14

2.5

 

NOT AVAILABLE

 

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380 – 415

50/60

3

3

11

15

14

2.5

 

 

 

 

 

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

*NOTE: Wire sizing listed in this table is based on Article 310, Table 310.16 of the NEC; at 104°F (40°C) ambient temperature. Follow your local electrical codes. Use only copper conductors, rated for 194ºF (90°C) or higher, type THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority having jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase circuit breakers for single phase machines only; three phase circuit breakers for all others.

**M30 Control Models only.

Table 10

50

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Page 52
Image 52
Alliance Laundry Systems PHM802N, PHM798N manual M30 Control Models only