Allied Telesis AT-X210-16GT, AT-X210-9GT, AT-X210-24GT manual Cable Specifications, Type of Cable

Models: AT-X210-16GT AT-X210-24GT AT-X210-9GT

1 66
Download 66 pages 11.41 Kb
Page 35
Image 35

AT-x210-9GT, AT-x210-16GT, and AT-x210-24GT Switches Installation Guide

Cable Specifications

Table 7 contains the cable specifications for the twisted pair ports.

Table 7. Twisted Pair Cabling and Distances

 

 

Maximum

Speed

Type of Cable

Operating

 

 

Distance

 

 

 

10 Mbps

Standard TIA/EIA 568-B-compliant

100 m (328 ft)

 

Category 3 or better shielded or

 

 

unshielded cabling with 100 ohm

 

 

impedance and a frequency of 16

 

 

MHz.

 

 

 

 

100 Mbps

Standard TIA/EIA 568-A-compliant

100 m (328 ft)

 

Category 5 or TIA/EIA 568-B-

 

 

compliant Enhanced Category 5

 

 

(Cat 5e) shielded or unshielded

 

 

cabling with 100 ohm impedance

 

 

and a frequency of 100 MHz.

 

 

 

 

1000 Mbps

Standard TIA/EIA 568-A-compliant

100 m (328 ft)

 

Category 5 or TIA/EIA 568-B-

 

 

compliant Enhanced Category 5

 

 

(Cat 5e) shielded or unshielded

 

 

cabling with 100 ohm impedance

 

 

and a frequency of 100 MHz.

 

 

 

 

Note

The twisted pair ports on the switch feature auto-MDI when operating at 10, 100, or 1000 Mbps. A port is configured as MDI or MDI-X when it is connected to an end node. Consequently, you can use a straight-through twisted pair cable when connecting any type of network device to a port on the switch.