AT-FH812u and AT-FH824u Software
20
RMON
Configuration Use the RMON Configuration screen (Figure13) to enable/disable RMON support
or to attach the Agent Module to either the 10 or 100 Mbps segment. Table12
describes the RMON configuration parameters.
------------------------------------------------------------
RMON Configuration
10M Segment RMON : Disable
100M Segment RMON : Enable
Full Segment Enable : NO
Agent Attached to : 100M
<APPLY> <OK> <CANCEL>
Use ESC for help. Use arrow keys to move.
<Enter> to confirm.
------------------------------------------------------------
Figure 13 RMON Configuration Screen
Note
To use the functions provided by RMON, you must access the hub's agent with
an SNMP management program that supports RMON.
Table 12 RMON Configuration Parameters
Parameters Description
10M Segment RMON Enable/disable RMON support for 10 Mbps segment.
100M Segment RMON Enable/disable RMON support for 100 Mbps segment.
Full Segment Enable If RMON is enabled for the segment attached to the Agent
Module, and this option is set to YES, then all 9 RMON
groups are used. If this option is set to NO, only RMON
groups 1, 2, 3 and 9 are used.
Agent Attached to1
1. If no path exists between the two repeater segments via an Inter nal Switch Module or by other
external network connections, then the SNMP, HTTP and Telnet protocols will only have man-
agement access to the repeater segment attached to the Agent Module.
Attach the Agent Module to either the 10 or 100 Mbps
segment. Note that only the segment attached to the agent
can provide full RMON support.