NOTE: The -L parameter cannot designate an output log file. A default log file named with the DNS name or the IP address is created in the same directory where CPQLOCFG is launched.

6.Click Next. A screen displays the options for naming the task, defining the query association, and setting a schedule for the task.

7.Enter a task name in the Enter a name for this task field.

8.Select the query that had been created earlier, for example "Mgmt Processors."

9.Click Schedule to define when the Application Launch task will run. A schedule configuration window appears.

10.Click OK to set the schedule.

NOTE: The default schedule for a control task is Now.

11.Click Finish to save the Application Launch task.

12.Click the Execute a Task icon (the green triangle) to execute the Group Administration.

Batch processing using the Lights-Out Configuration Utility

Group Administration can also be delivered to RILOE II through batch processing. The components used by batch processing are the Lights-Out Configuration Utility, an RIBCL file, and a batch file.

The following example shows a sample batch file that can be used to perform the Group Administration for RILOE II:

REM Updating the Remote Insight Lights-Out Edition II board REM Repeat line for each board to be updated

REM

CPQLOCFG -S RIB1 -F C:\...SCRIPT.XML -L RIB1LOG.TXT -V CPQLOCFG -S RIB2 -F C:\...SCRIPT.XML -L RIB2LOG.TXT -V CPQLOCFG -S RIB3 -F C:\...SCRIPT.XML -L RIB3LOG.TXT -V

.

.

.

RIBNLOG -S RIBN -F C:\...SCRIPT.XML -L LOGFILE.TXT -V

The Lights-Out Configuration Utility overwrites any existing log files.

Lights-Out Configuration Utility parameters

-S is the switch that determines the RILOE II that is to be updated. This switch is either the DNS name or IP address of the target server.

Do not use this switch if you are launching from Systems Insight Manager. Systems Insight Manager will provide the address of the RILOE II when CPQLOCFG.EXE is launched.

-F is the switch that gives the full path location and name of the RIBCL file that contains the actions to be performed on the board.

-U and -P specify the user login name and password. These options allow the login information within the script file to be overridden and allows the login information to be left out of the script.

Be sure that the Lights-Out Configuration Utility is in a directory referenced by the PATH environment variable. Any log files generated are placed in the same directory as the Lights-Out Configuration Utility executable

The switches -L and -V might or might not be set depending on the IT administrator's preferences.

-L is the switch that defines where the log file will be generated and what the file name will be. If this switch is omitted, a default log file with the DNS name or the IP address is created in the same directory used to launch CPQLOCFG.

Scripting, command line, and utility options 128