SET_VF_STATUS Runtime Errors
The possible SET_VF_STATUS error messages are:
•RIB information is open for
•An invalid Virtual Floppy option has been given.
•User does not have correct privilege for action.
•
GET_HOST_POWER_STATUS
The GET_HOST_POWER_STATUS command displays the server power state from the Virtual Power Button cable. The GET_HOST_POWER_STATUS command must be displayed within a SERVER_INFO element, and SERVER_INFO must be in write mode. The user must be logged in with login privilege to execute this command.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<SERVER_INFO MODE="write">
<GET_HOST_POWER_STATUS/>
</SERVER_INFO>
</LOGIN>
</RIBCL>
GET_HOST_POWER_STATUS Parameters
There are no parameters for this command.
GET_HOST_POWER_STATUS Runtime Errors
The possible GET_HOST_POWER_STATUS error messages include:
•Host power is OFF.
•Host power is ON.
GET_HOST_POWER_STATUS Return Messages
The following information is returned within the response:
<GET_HOST_POWER
HOST POWER="OFF"
/>
SET_HOST_POWER
The SET_HOST_POWER command sets the Virtual Power Button feature. This feature is used to turn the server on or off if the feature is supported. The SET_HOST_POWER command must be displayed within a SERVER_INFO element, and SERVER_INFO must be in write mode. The user must be logged in with reset server privilege to execute this command.
Example:
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<SERVER_INFO MODE="write">
Scripting, command line, and utility options 167