Example:

<RIB_INFO MODE="write">

………RIB_INFO commands …… </RIB_INFO>

RIB_INFO parameters

MODE is a specific string parameter with a maximum length of 10 characters that specifies what you intend to do with the information. Valid arguments are "read" and "write."

Write mode enables both reading and writing of RILOE II information. Read mode prevents modification of RILOE II information.

RIB_INFO runtime errors

None

RESET_RIB

The RESET_RIB command is used to reset RILOE II. For this command to parse correctly, the command must appear within a RIB_INFO command block, and RIB_INFO MODE can be set to read or write. The user must have the configure RILOE II privilege to execute this command.

Example:

<RIBCL VERSION="2.0">

<LOGIN USER_LOGIN="Admin" PASSWORD="Password">

<RIB_INFO MODE = "write">

<RESET_RIB/>

</RIB_INFO>

</LOGIN>

</RIBCL>

RESET_RIB parameters

None

RESET_RIB runtime errors

The possible RESET_RIB error message include:

User does not have correct privilege for action. CONFIG_ILO_PRIV required.

GET_NETWORK_SETTINGS

The GET_NETWORK_SETTINGS command allows the user to retrieve the network settings.

GET_NETWORK_SETTINGS must display inside a RIB_INFO block. The user must have login privilege to execute this command.

Example:

<RIBCL VERSION="2.0">

<LOGIN USER_LOGIN="adminname" PASSWORD="password">

<RIB_INFO MODE="read">

<GET_NETWORK_SETTINGS/>

</RIB_INFO>

Scripting, command line, and utility options 149

Page 149
Image 149
HP 232664-006 manual Resetrib, Getnetworksettings