</LOGIN>

</RIBCL>

MOD_TWOFACTOR_SETTINGS parameters

All of the following parameters are optional. If a parameter is not specified, then the parameter value for the specified setting is preserved.

AUTH_TWOFACTOR_ENABLE enables or disables Two-Factor authentication. The possible values are "Yes" and "No."

CERT_REVOCATION_CHECK causes RILOE II to use the CRL distribution point attribute of the client certificate, to download the CRL and check against revocation. The possible values are "Yes" and "No." If this setting is set to Yes, and the CRL cannot be downloaded for any reason, authentication will be denied.

CERT_OWNER_SAN causes RILOE II to extract the User Principle Name from the Subject Alternative Name, and use that for authentication with the directory, for example: username@domain.extension.

CERT_OWNER_SUBJECT causes RILOE II to derive the user's distinguished name from the subject name. For example if the subject name is "/DC=com/DC=domain/OU=organization/CN=user", RILOE II will derive: "CN=user,OU=organization,DC=domain,DC=com".

The CERT_OWNER_SAN and CERT_OWNER_SUBJECT settings are only used if directory authentication is enabled.

IMPORT_CA_CERTIFICATE imports the certificate into RILOE II as the trusted Certificate Authority. RILOE II will only allow client certificates that are issued by this CA. A Trusted CA certificate must be configured in RILOE II in order for Two-Factor authentication to function.

IMPORT_USER_CERTIFICATE imports the certificate into RILOE II and maps it to the specified local user. Any client that authenticates with this certificate will authenticate as the local user to which it is mapped. The SHA1 hash of this certificate will be displayed on the Modify User web page for the user to whom it is mapped. If RILOE II is using directory authentication, client certificate mapping to local user accounts is optional and only necessary if authentication with local accounts is desired.

The IMPORT_CA_CERTIFICATE and IMPORT_USER_CERTIFICATE settings require that base64 encoded certificate data be included between the begin and end tags.

MOD_TWOFACTOR_SETTINGS runtime errors

The possible MOD_TWOFACTOR_SETTINGS error messages include:

RIB information is open for read-only access. Write access is required for this operation.

This setting cannot be changed while Shared Network port is enabled.

RILOE II has been configured to use shared network port, which will not function if Two-factor authentication is enabled

This setting cannot be enabled unless a trusted CA certificate has been imported. A CA certificate must be imported before enabling Two-factor authentication.

User does not have correct privilege for action. CONFIG_ILO_PRIV required.

Scripting, command line, and utility options 172